How does the frequency converter control the motor speed?

2023-05-20 13:30:44

1. why can the rotation speed of the motor be changed freely?


Motor rotation speed unit: r/min rotation times per minute, or rpm


For example: 2 pole motor 50hz3000[r/min]


4 pole motor 50hz1500[r/min]


Conclusion: the rotating speed of motor is proportional to the frequency


The rotation speed of induction AC motor (hereafter referred to as motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed according to the working principle of the motor. Since the pole value is not a continuous value (a multiple of 2, for example, the number of poles is 2, 4, 6), it is generally uncomfortable and the motor speed is adjusted by changing the value.


In addition, the frequency can be adjusted outside the motor and then supplied to the motor, so that the motor rotation speed can be freely controlled.


Therefore, the inverter with the purpose of controlling frequency is the best equipment for motor speed regulation equipment.


n=60f/p

n: Synchronization speed

f: Power frequency

p: Motor pole number


Conclusion: changing frequency and voltage is the best method of motor control


If only the frequency is changed without changing the voltage, the frequency reduction will cause the motor to be out of overvoltage (overexcitation), which may cause the motor to be burnt out. Therefore, the frequency converter must change the voltage at the same time. When the output frequency is above the rated frequency, the voltage can not be increased continuously, and the maximum voltage can only be equal to the rated voltage of the motor.


For example, in order to reduce the rotation speed of the motor by half, the output frequency of the converter is changed from 50Hz to 25Hz, and the output voltage of the converter needs to be changed from 400V to about 200V


2. what is the output torque of the motor when the rotation speed (frequency) of the motor changes?


The starting torque and maximum torque of the inverter drive shall be less than that of the direct power frequency power supply


The motor starts and accelerates greatly when power supply is supplied by power supply, and when using frequency converter, these shocks will be weaker. Direct starting of power frequency will produce a large starting current. When using frequency converter, the output voltage and frequency of the inverter are gradually added to the motor, so the starting current and impact of the motor are smaller.


In general, the torque generated by the motor will decrease with the decrease of frequency (speed reduction). The actual data reduced will be explained in some frequency converter manuals.


By using flux vector control converter, the shortage of torque in low speed motor will be improved, and enough torque can be output even in low speed area.


3. When the frequency converter is adjusted to more than 50 Hz, the output torque of the motor will be reduced


The motor is usually designed and manufactured according to the voltage of 50 Hz, and its rated torque is also given in this voltage range. Therefore, the speed regulation under the rated frequency is called constant torque speed regulation. (t = te, P < = PE)


When the frequency converter output frequency is greater than 50 Hz frequency, the torque produced by the motor will decrease in a linear relationship inversely proportional to the frequency.


When the motor runs at the frequency of more than 50 Hz, the size of the motor load must be considered to prevent the insufficient output torque of the motor.


For example, the torque produced by a motor at 100Hz should be reduced to about half of the torque produced at 50Hz.


Therefore, the speed regulation above the rated frequency is called constant power speed regulation. (P = UE * IE)


4. Application of frequency converter above 50 Hz


As we all know, for a specific motor, its rated voltage and rated current are constant.


For example, the rated value of frequency converter and motor is 15kw / 380V / 30a, and the motor can work above 50 Hz.


When the speed is 50 Hz, the output voltage of the inverter is 380V and the current is 30A. At this time, if the output frequency is increased to 60Hz, the maximum output voltage and current of the inverter can only be 380V / 30A. Obviously, the output power remains unchanged, so we call it constant power speed regulation


What is the torque situation?


Because P = WT (W: angular velocity, t: torque). Because P is constant, w increases, so the torque decreases accordingly.


We can also look at it from another perspective


Stator voltage U = e + I * r (I is current, R is electronic resistance, e is induced potential)


It can be seen that when u and I are constant, e remains the same


And E = k * f * x, (K: constant, F: frequency, X: flux), so when f is from 50 to > 60Hz, x will decrease correspondingly


For the motor, t = k * I * x, (K: constant, I: current, X: flux), so the torque T decreases with the decrease of flux X


At the same time, when I * r is very small when I * r is less than 50 Hz, when u / F = E / F is constant, the flux (x) is constant. The torque T is proportional to the current. This is why the overload (torque) capacity of the inverter is usually described by the over-current capacity of the converter, which is also called constant torque speed regulation (constant rated current --- > maximum torque constant)


Conclusion: the output torque of the motor will decrease when the frequency of inverter increases from 50 Hz to above


5. Other factors related to output torque


The output current capacity of the inverter is determined by the heating and cooling capacity, which affects the output torque capacity of the inverter.


Carrier frequency: in general, the rated current marked by frequency converter is the value with the highest carrier frequency, which can ensure continuous output under the highest ambient temperature. When the carrier frequency is reduced, the motor current will not be affected. But the heating of components will be reduced.


Ambient temperature: as if not because of the detection of low ambient temperature on the inverter protection current value


Altitude: the increase of altitude will affect the heat dissipation and insulation performance. Generally, it is not considered if the altitude is below 1000m. It is OK to reduce the capacity by 5% every 1000m


Special frequency converter


label

QR code

The public,

Mobile station
The public, Mobile station

Contact

未標題-8.png 0755-81719517
未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

Navigation

Home          About

Product      Case

Solution      Service

Job      News

Contact          

Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
主站蜘蛛池模板: 菠萝蜜在线视频观看 | 免费一级毛片 | 久久蜜桃 | 久久精品综合免费观看 | 中文在线日本免费永久18近 | 国产香蕉网 | 亚洲成a人片在线观看中文动漫 | 四虎国产精品永久一区 | 亚洲天堂男 | 亚洲日韩aⅴ在线视频 | 国产视频最新 | 免费韩国美女爽快一级毛片 | 日本中文字幕视频在线看 | 日本中文字幕一区二区 | 久久99国产精品久久99无号码 | 青青草国产一区二区三区 | 九九久久99综合一区二区 | 天天久久综合 | 99re国产精品视频首页 | 大又大又粗又爽女人毛片 | 玖玖精品在线视频 | 欧美日韩1区 | 一级特黄aaa大片29 | 毛片区| 国产一级精品高清一级毛片 | 久久免费视频网 | 国产女人好紧好爽 | 久久网视频 | 白色强人粤语版在线观看港剧网 | 国产精自产拍久久久久久 | 国产大片中文字幕 | 亚洲综合国产 | 尹人在线 | 色猫咪在线 | 两个人的视频全免费观看在线 | 天堂在线.www资源在线观看 | 免费人成网 | 一区二区不卡久久精品 | 欧美在线香蕉在线现视频 | 亚洲一区在线观看视频 | 一区二区视频免费观看 |